Danfoss VLT® Soft Starter MCD 600
The VLT® Soft Starter MCD 600 combines the latest in advanced controls and protections with an increased level of intelligence for superior performance in fixed-speed applications.
The MCD 600 is more flexible than ever to install, thanks to a wide variety of Ethernet and serial-based communication option cards, application-dedicated smart cards and support for eight languages.
The integrated bypass ensures both extremely high efficiency and harmonic-free operation at full speed, reducing energy consumed and required cooling capacity.
Ease of use is also greatly increased with new capabilities, such as the pump-clean function, PowerThrough operation, and calendar or run time-based scheduling. Furthermore, enhanced protection ensures more uptime.
- Quick set-up menu – Adjusts key parameters to suit the application, reducing start-up time
- Log menu – up to 348 individual events recorded and eases analysis of the application
- Pump clean functionality – Helps to dislodge debris from an impeller without any extra components
- Integrated USB port (Parameter copy, data logging, firmware updates) – Reduced start-up/upgrade time and easy access to operational data
- AAC Adaptive Acceleration Control – Automatically adapts to the chosen starting and stopping profile
- Reversing contactor control – Allows for soft starting in any direction– Does not require any external contactors
- Jog (slow-speed operation) – Application flexibility
- Auto Reset – Less downtime
- Internal bypass contactors – Save space and wiring, reduces heat dissipation when running, and eliminates costly external components
- Inside Delta (6-wire connection) – Smaller soft starter can be selected
- PowerThrough operation – Utilizes 2-phase control when one phase is damaged (shorted SCR)
- Expanded motor and controller protections (Over/Under-power, Over/Under-voltage) – Additional protection reduces downtime
- Multiple languages – Eases commissioning, reducing start-up time
- Onscreen, dynamic QR-codes – Provides information about the MCD 600, including serial number and failure information
Mains voltage (L1, L2, L3)
- MCD6-xxxxB-T5 200-525 VAC (±10%)
- MCD6-xxxxB-T7 380-690 VAC (±10%) (in-line connection)
Control voltage (terminals A4, A5, A6)
- CV1 (A8, A9): 24 VAC/VDC (±20%), 2.8 A
- CV2 (A8, A9): 110-120 VAC (+10%/-15%), 600 mA
- CV2 (A8, A9): 220-240 VAC (+10%/-15%), 600 mA
- Mains frequency: 50/60 Hz (± 5%)
- Rated insulation voltage to earth: 690 VAC
- Rated impulse withstand voltage: 6 kV
- Form designation: Bypassed or continuous, semiconductor motor starter form 1
- Coordination with semiconductor fuses: Type 2
- Coordination with HRC fuses: Type 1
Electromagnetic capability (compliant with EU Directive 2014/35/EU)
- EMC Immunity IEC 60947-4-2
- EMC Emissions IEC 60947-4-2 Class B
Inputs
- Input rating Active 24 VDC, 8 mA (approximately)
- Motor thermistor (TER-05, TER-06) Trip >3.6 kΩ, reset >1.6 kΩ
Outputs
- Relay outputs: 10 A @ 250 VAC resistive, 5 A @ 250 VAC AC15 pf 0.3
- Main Contactor (13, 14): Normally open
- Relay output A (21, 22, 23): Changeover
- Relay output B (33, 34): Normally open
- Analog Output (AO-07, AO-08): 0-20 mA or 4-20 mA (selectable)
- Maximum load: 600 Ω (12 VDC @ 20 mA) (accuracy ±5%)
- MCD6-0020B ~ MCD6-0129B: IP20
- Protection MCD6-0144B ~ MCD6-0579C: IP00
- Operating temperature: -10° C to 60° C, above 40° C with derating
- Storage temperature: -25° C to + 60° C
- Operating altitude: 0-1000 m, above 1000 m with derating
- Humidity: 5% to 95% relative humidity
- Pollution degree: Pollution Degree 3
- Vibration: IEC 60068-2-6